GC2 GoControl - Sensor Information Part 2

2GIG-PIR1-345 Motion Detector

2GIG-PIR1-345_Motion_Detector.jpg

Specifications

  • 345 MHz sends supervisory signal every 70 minutes
  • RF Range 100' from panel
  • Operating temperature 32° F to 120° F standard installation
  • Operating temperature 50° F to 90° F if set for pet immunity

Pet Immunity Setup

  • Mount 7.5' from floor flat against wall with no downward tilt
  • Do not face windows, tall furniture or stairs
  • Set back jumper to low
  • Set pet jumper by pet weight 33 pounds or 55 pounds

Testing

  • Place magnet over arrow on side of motion for 3 seconds
  • LED turns ON then flashes on movement
  • Move in front of motion to test
  • Test exits after 1 minute

2GIG-CO1-345 Carbon Monoxide Detector

1.JPG

Specifications

  • Discontinued, replaced by 2GIG-CO3-345
  • Sensor Life 6 years
  • 345 MHz sends a supervisory signal every 70 minutes
  • Trouble beeps can be silenced once for 7 minutes by pressing test button
  • CR123A 3-Volt Lithium, 1 year estimated battery life
  • RF Range up to 100' from panel
  • Temperature Rating 32°F to 120°F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

Installation

  • Wall Mount at least 6" from ceiling or ceiling mounted at least 12 inches away from wall
  • Install within 10' of sleeping areas

Testing

  • Press and release Test button to test smoke sounder
  • Press Test for 20 seconds to trigger smoke detector test to panel

Status LED

  • Normal = Green flash every 12 seconds
  • Alarm/Test = Red flash every 12 seconds, 4 sounder beeps
  • Power Up = Red, yellow, and green LED's flash every 12 seconds, 1 chirp on power-up
  • Trouble = Yellow flash every 6 seconds, 1 chirp every 45 seconds
  • Low Battery = Yellow flash every 12

2GIG-CO3-345 Carbon Monoxide Detector

2.JPG

Specifications

  • Carbon Monoxide Element Life 5 years
  • 345 MHz sends a supervisory signal every 70 minutes
  • RF Range up to 100' from panel
  • 85 dB sounder
  • Trouble beeps can be silenced once for 7 minutes by pressing test button
  • CR123A 3-Volt Lithium, 1 year estimated battery life
  • Temperature Rating 40°F to 100°F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

Installation

  • Wall Mount at least 6 inches from ceiling or ceiling mounted at least 12 inches away from wall
  • Install within 10' of sleeping areas

Testing

  • Press and release Test button to test smoke sounder
  • Hold Test button 20 seconds to trigger smoke detector test to panel

Status LED

  • Normal = Green flash every 12 seconds
  • Alarm/Test = Red flash every 12 seconds, 4 sounder beeps
  • Power Up = Red, yellow, and green LED's flash every 12 seconds, 1 chirp on power-up
  • Trouble = Yellow flash every 6 seconds, 1 chirp every 45 seconds
  • Low Battery = Yellow flash every 12 seconds, 1 chirp every 45 seconds
  • Sensor End of Life = Red LED flashes every 10 seconds, 1 beep every 45 seconds
  • Tamper = Red, yellow, and green flash every 12 seconds

2GIG-DW10-345 Door Sensor

2GIG-DW10-345_Door_Window_Sensor.jpg

Specifications

  • 345 MHz sends a supervisory signal every 70 minutes
  • 2 CR2032 3-Volt Lithium, 5 year estimated battery life
  • RF Range up to 100' from panel
  • Temperature Rating 32° F to 120° F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

2GIG-FF-345 FireFighter

2GIG-FF-345_FireFighter.jpg

Specifications

  • Monitors existing hardwire Smoke Detectors
  • Reports 30 seconds after smoke detector internal sounder activates
  • Smoke Detectors must support UL Temporal 3 tones (3 beeps + pause + 3 beeps)
  • 345 MHz sends a supervisory signal every 64 minutes
  • CR123A 3-Volt Lithium battery, estimated life 5 years
  • RF range up to 100' from panel
  • Temperature Rating 32°F to 120°F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

Installation

  • Mount 6" with microphone facing smoke detector

Status LED

  • Off = Normal
  • Yellow Flash = Smoke Detector Sounder detected
  • In Alarm = Red 3 seconds, then red flash
  • Tamper = Red 3 seconds
  • Power Up = Red flash + green flash
  • Test = Green 3 seconds

2GIG-FT1-345 Flood Temp Sensor

5.JPG

Specifications

  • Flood detection (using external probe): Activates 3 minutes after water detection
  • High temperature alarm activates if 95 degrees for more than 5 minutes
  • Low temperature alarm activates if 41 degrees or lower for more than 5 minutes
  • 345 MHz sends a supervisory signal every 70 minutes
  • 2 CR2032 3-Volt Lithium, 5 year estimated battery life
  • RF Range up to 100' from panel
  • Operating Temperature 32°F to 120°F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

2GIG-GB1E-345 Glassbreak Detector

6.JPG 7.JPG

Specifications

  • 345 MHz sends supervisory signal every 70 minutes
  • 15' detection range
  • 2 CR123A 3-Volt Lithium batteries, 5 year estimated battery life
  • RF Range up to 100' from panel
  • Operating temperature 32° F to 120° F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e

Sensor Test

  • Hold Test button for 2 seconds, red LED turns on, green LED blinks once
  • Activate glassbreak tester by the window, green LED senses crash, red LED senses thud
  • Sensor tests ends after 90 seconds

2GIG-Panic1-345 Remote Panic

8.JPG

Specifications

  • Available as belt clip, watch, or pendant panic
  • Hold button 3 to 4 seconds until LED turns on to activate
  • Water resistant but not waterproof
  • Can be used in the shower but not while in the bath or swimming
  • CR2032 3-Volt Lithium, up to 3 year estimated battery life
  • RF Range up to 100' from panel
  • Operating temperature 32° F to 120° F

Compatibility

  • 2GIG GC2 Go Control
  • 2GIG GC2e
  • 2GIG GC3
  • 2GIG GC3e