How to Program a Door/Window Sensor to a Lynx Plus L3000

Follow the steps below to connect a door/window sensor to the Lynx Plus L3000.


Step-by-Step Instructions:

  1. Enter your default installer code 4112, then press 800.

    01a Enter Program Mode 150x36 01b 20 Installer Code 150x36


  2. Enter an unused zone number between 02 and 25, then press *.
  3. 02a 56a Zone Number 1 150x36 02b 56a Zone Number 2 150x36


  4. Enter the zone type as 01, then press *.
  5. 03a 56b Zone Type 1 Not Used 150x36 03b 56b Zone Type 2 Entry Exit 150x36


  6. Enter the report code (A0) as 10, then press*.
  7. 04a 56c Report Code 1 150x36 04b 56c Report Code 2 150x36


  8. Leave the RF type as 3, then press *.
  9. 05 56d RF Type 1 150x36


  10. Trip the sensor twice by opening the door or window, then press *.
  11. 06a 56f RF Learn 1 150x36 06b 56f RF Learn 2 150x36


  12. Press 1, then enter word descriptors, enter 04 for door or 80 for window. Press 8 to exit the voice descriptor menu. Alternatively, you may press 06 to enter additional words.
  13. 07a 56g Zone Descriptor 6 150x36 07b 56g Zone Descriptor 7 150x36


  14. Press *99 to exit programming mode, then enter 800.
  15. XX Exit Program Mode 150x36



Need instructions for sensor placement and mounting? Click here.


If you need further assistance, you can text a Support Representative any time at 469.513.8685.