How to Program a Door/Window Sensor to the Concord 4 Panel

Follow the steps below to connect a door/window sensor to the Concord 4 panel.


Step-by-Step Instructions:

  1. While your system is in a disarmed state and displays the default date and time home screen, press 8, enter your default installer code 4321, then press 00.
  2. 1 60-746 Alpha Ready to Arm 166x40 2 60-746 Alpha Enter Code 166x40 3 60-746 Alpha Enter Command 166x40


  3. Press 080, then press #.
  4. 1.a Learn Sensor 01 Shortcut 080 166x40 1.b Learn Sensor 02 Learn Sensors 166x40


  5. Enter partition 1 to 6, then press #.
  6. 2.a Edit Sensors 04 Partition 1 166x40 2.b Edit Sensors 04 Partition 2 166x40


  7. Enter sensor group 10 for a door/window sensor with an entry/exit delay, then press #.
  8. 3.a Learn Sensor 04 Group 0 166x40 3.b Learn Sensor 04 Group 10 166x40


  9. Activate sensor tamper or trip sensor to learn. When successful, the Concord 4 display prompts you to trip another sensor.
  10. 4.a Learn Sensor 05 Trip Sensor 1 166x40 4.b Learn Sensor 06 Trip Sensor 2 166x40


  11. Press * to exit to sensor group entry, then press # to exit sensor programming.
  12. 5.a Learn Sensor 04 Group 10 166x40 5.b Learn Sensor 02 Learn Sensors 166x40


  13. Press * through system programming, then press A or B until you see "exit programming ready" displayed. Press # to return to the home screen.
  14. x.1 Concord System Programming 166x40 x.2 60-746 Alpha Time Date 8 166x40 x.3 60-746 Alpha Ready to Arm 166x40