YRD210 Door Lock—Resolving a Malfunction

Resolving Errors on a New Device:

If this error occurs on a newly installed device, it is usually an indication that the Z-Wave device is too far from the panel to maintain a signal.

Determine if a signal extender may be your best option. Most Z-Wave devices that plug into a power outlet can be used to relay a Z-Wave signal.

You can test if this will resolve the issue by bringing panel closer to the Z-Wave Device, if it is powered by backup battery. Clear the error and see if the issue continues.


Resolving Errors on a Pre-Existing Device:

If the error occurs on a device that has been installed for a long time, it may be that the batteries are too low to maintain a signal.

Learn how to replace the batteries in the Yale YRD210 door lock here: YRD210 Door Lock—Battery Replacement.

You will also need to clear the error from the panel memory. Select your panel below to view instructions:

Qolsys:


2GIG:


Interlogix: